Master Line installation elements for professional and industrial systems Sistem Air Pro.
Get the maximum and touch the impossible.
Discover the complementary components for Sistem Air PRO systems
The non-return valve must be fitted to each individual motor if several vacuum units are combined in the same system.
It should be installed directly on the motor’s air vent connection to ensure that the air vacuum is maintained when one motor is in use and the other is switched off.
Article | Measure | Ø Tube | For motors |
0110001 | 2” | 63 | 3500.1M 3503.2M |
0110003 | 3” | 80 | 3500.3M 3500.5M 3503.6M 3513.4M |
0110002 | 4” | 100 | 3503.7M 3503.11M |
The air silencer is installed directly on the engine unit to dampen the noise.
More silencers can be added as needed.
Article | Measure | Ø Tube | For motors |
11001 | 2” | 63 | 3500.1M 3503.2M |
11002 | 3” | 80 | 3500.3M 3500.5M 3503.6M 3513.4M |
11003 | 4” | 100 | 3503.7M 3503.11M |
Metal exhaust kits make it possible to realise the initial part of the air exhaust in industrial engines and power plants for advanced civil use.
Under certain conditions of use, the expelled air may reach such temperatures that the PVC pipes may be damaged. In these cases it is advisable to make the exhaust in metal, sizing it appropriately to the diameter of the engine exhaust and the overall length of the exhaust.
The exhaust kits can be added together in order to realise the desired dust ejection line.
Article | Description |
7020.63 | Steel air exhaust kit Ø 60 |
7020.80 | Steel air exhaust kit Ø 80 |
7020.10 | Steel air exhaust kit Ø 100 |
The switchboard for motor start selection is used when several standard motors are installed on a single system, without an electronic speed converter.
The internal electronic system allows, by means of a resistive divider installed on the microswitch line, to pilot the switching on and off of one or more motors in the system, depending on the number of inlet sockets used, and to manage the operating hours of each individual motor group.
In fact, it is possible to reverse the starting priority of the motors by means of a cyclic switch, balancing the wear status of the motors.
Article | Motors max | Power supply V ac | For motors |
3301.6 | 2 | 220/240 | 3500.3M 3500.5M |
3301.0 | 3 | 220/240 | 3500.3M 3500.5M |
The electronic panel for controlling the speed of the motor unit is used when an electronic type motor is installed.
The internal electronic system allows, by means of a resistive divider installed on the microswitch line, to control the speed of the motor unit, depending on the number of inlet sockets used, in order to achieve the best performance with the lowest consumption.
The system provides up to four switching levels (4 speeds) and is suitable for all electronic units even of different power ratings.
Article | Motors max | For motors |
3301.6 | 1 x max 4 speed | 3503.2M 3513.4M 3503.6M 3503.7M 3503.11M |
Sleeve valves are used in all situations where it is necessary to open and close a section of pipeline automatically, even very frequently.
Inside them is a rubber diaphragm, resistant to abrasion and chemicals, which is inflated by compressed air controlled by a solenoid valve.
The control can be manual or automatic and ensures the hermetic opening or closing of the pipe.
Article | Description | Ø input | Pressure bar | Degree of protection |
1456.5MA | Pneumatic sleeve valve Ø 50 mm 230 V ac | 50 | 4,5 | IP65 |
1456.4MA | Pneumatic sleeve valve Ø 60 mm 230 V ac | 60 | 6 | IP65 |
1456.6MA | Pneumatic sleeve valve Ø 80 mm 230 V ac | 80 | 6 | IP65 |
The resistive divider is indispensable for varying the suction power with several sets of electric motors.
Each divider can accommodate up to four suction inlets, which can be connected together without any maximum limit.
Compliance with sanitary regulations, suction of dangerous materials, waste recovery and continuous use these are just some of the pluses offered by the system SISTEM AIR PRO.
There is always need for a central vacuum system because cleaning well is an important part of the quality of your work.
For the scheduled maintenance of the central vacuum unit, the instructions in the technical manual provided and the instructions on the user interface display must be followed.
In particular, these periodic operations mainly concern cleaning the filter, emptying the dust collection container, replacing the bag, checking the correct operation of the electric motor and any obstruction of the air outlet.
All interventions not included in scheduled maintenance by the user must be performed by qualified workers
The Sistem Air central vacuum system is the essential system for all homes. It ensures healthy environments with regular cleaning.
A simple and durable integrated system. The only one in the world that expels micro-dust, dust mites, allergens, pollutants, bacteria and viruses.
Sistem Air Pro, on the other hand, meets the needs of professionals and industries. Beyond simple cleaning, a working tool.
Tel. +39 0381 650082
WhatsApp +39 340 4090146
Email info@sistemair.it
Via Cilavegna, 53
27020 Gravellona Lomellina (PV)
ITALIA
Sistem Air Group – Tecnoplus S.r.l. 2017 – 2023 - P. IVA IT01432070181 Num. REA PV 185869 - Capitale sociale 99.900 € i.v.